Physics-Informed Condition Monitoring of SiC Power Modules

The full document

Click here to download the full deck.

The problem

Sintered SiC modules show complex, non-monotonic degradation due to wire-bond lift-off, making health estimation harder than in conventional solder-based modules.

The solution

A lightweight physics-informed framework combines cumulative damage features, monotonicity constraints, and probabilistic uncertainty estimation.

Performance impact

The approach reduces lifetime-fraction estimation error by up to ~60% versus the reference baseline, with strong cross-validation stability.

The proof

It was validated on an industrial Infineon power-cycling dataset across multiple operating conditions and SiC modules.